== Key Reference ==
{| class="wikitable sortable"
|-
! Key !! Value
|-
| 1001  || NEW_FIRMWARE_AVAILABLE
|-
| 1002  || SMART_TASK_TRIGGERED_EVENT
|-
| 1003  || GATEWAY_REBOOT_NOTIFICATION
|-
| 2051  || OPTION_APP_TOKEN
|-
| 3300  || SENSOR
|-
| 3311  || LIGHT
|-
| 3312  || PLUG
|-
| 5001  || LOSS_OF_INTERNET_CONNECTIVITY
|-
| 5601  || MIN_MSR_VALUE
|-
| 5602  || MAX_MSR_VALUE
|-
| 5603  || MIN_RNG_VALUE
|-
| 5604  || MAX_RNG_VALUE
|-
| 5605  || RESET_MIN_MAX_MSR
|-
| 5700  || SENSOR_VALUE
|-
| 5701  || UNIT
|-
| 5706  || COLOR
|-
| 5709  || COLOR_X
|-
| 5710  || COLOR_Y
|-
| 5712  || TRANSITION_TIME
|-
| 5750  || TYPE
|-
| 5751  || SENSOR_TYPE
|-
| 5805  || CUM_ACTIVE_POWER
|-
| 5820  || POWER_FACTOR
|-
| 5850  || ONOFF
|-
| 5851  || DIMMER
|-
| 5852  || ON_TIME
|-
| 9001  || NAME
|-
| 9002  || CREATED_AT
|-
| 9003  || INSTANCE_ID
|-
| 9009  || SCENE_LINK
|-
| 9014  || NOTIFICATION_STATE
|-
| 9015  || NOTIFICATION_EVENT
|-
| 9016  || SMART_TASK_TEMPLATE
|-
| 9017  || NOTIFICATION_NVPAIR
|-
| 9018  || HS_ACCESSORY_LINK
|-
| 9019  || REACHABILITY_STATE
|-
| 9020  || LAST_SEEN
|-
| 9023  || NTP_SERVER
|-
| 9024  || TIME_REMAINING_IN_SECONDS
|-
| 9029  || VERSION
|-
| 9030  || REBOOT
|-
| 9031  || RESET
|-
| 9032  || FORCE_CHECK_OTA_UPDATE
|-
| 9033  || SESSION_ID
|-
| 9034  || UPDATE_FIRMWARE
|-
| 9035  || GATEWAY_NAME
|-
| 9036  || MASTER_TOKEN_TAG
|-
| 9037  || OTA_UPDATE
|-
| 9038  || GROUP_ID
|-
| 9039  || SCENE_ID
|-
| 9040  || SMART_TASK_TYPE
|-
| 9041  || REPEAT_DAYS
|-
| 9042  || START_ACTION
|-
| 9043  || END_ACTION
|-
| 9044  || TRIGGER_TIME_INTERVAL
|-
| 9045  || GROUP_SETTINGS
|-
| 9046  || START_TIME_HR
|-
| 9047  || START_TIME_MN
|-
| 9048  || END_TIME_HR
|-
| 9049  || END_TIME_MN
|-
| 9050  || SMART_TASK_ACTION
|-
| 9051  || SHORTCUT_ICON_REFERENCE_TYPE
|-
| 9052  || GATEWAY_REBOOT_NOTIFICATION_TYPE
|-
| 9054  || OTA_UPDATE_STATE
|-
| 9055  || GATEWAY_UPDATE_PROGRESS
|-
| 9056  || GATEWAY_UPDATE_DETAILS_URL
|-
| 9057  || SCENE_INDEX
|-
| 9058  || SCENE_ACTIVATE_FLAG
|-
| 9059  || CURRENT_TIMESTAMP
|-
| 9061  || COMMISSIONING_MODE
|-
| 9063  || AUTH_PATH
|-
| 9064  || SESSION_LENGTH
|-
| 9066  || OTA_TYPE
|-
| 9068  || IKEA_MOODS
|-
| 9069  || UPDATE_ACCEPTED_TIMESTAMP
|-
| 9070  || USE_CURRENT_LIGHT_SETTINGS
|-
| 9071  || GATEWAY_TIME_SOURCE
|-
| 9090  || CLIENT_IDENTITY_PROPOSED
|-
| 9091  || NEW_PSK_BY_GW
|-
| 9994  || TIME_ARRAY
|-
| 9995  || GROUP_LINK_ARRAY
|-
| 15001 || DEVICES
|-
| 15002 || HS_LINK
|-
| 15004 || GROUPS
|-
| 15005 || SCENE
|-
| 15006 || NOTIFICATIONS
|-
| 15009 || SWITCH
|-
| 15010 || SCHEDULES
|-
| 15011 || GATEWAY
|-
| 15012 || GATEWAY_DETAILS
|-
| 15013 || LIGHT_SETTING
|}


[[Kategorie:Projekte]]
[[Kategorie:Projekte]]

Version vom 9. März 2018, 23:59 Uhr

Key Reference

Key Value
1001 NEW_FIRMWARE_AVAILABLE
1002 SMART_TASK_TRIGGERED_EVENT
1003 GATEWAY_REBOOT_NOTIFICATION
2051 OPTION_APP_TOKEN
3300 SENSOR
3311 LIGHT
3312 PLUG
5001 LOSS_OF_INTERNET_CONNECTIVITY
5601 MIN_MSR_VALUE
5602 MAX_MSR_VALUE
5603 MIN_RNG_VALUE
5604 MAX_RNG_VALUE
5605 RESET_MIN_MAX_MSR
5700 SENSOR_VALUE
5701 UNIT
5706 COLOR
5709 COLOR_X
5710 COLOR_Y
5712 TRANSITION_TIME
5750 TYPE
5751 SENSOR_TYPE
5805 CUM_ACTIVE_POWER
5820 POWER_FACTOR
5850 ONOFF
5851 DIMMER
5852 ON_TIME
9001 NAME
9002 CREATED_AT
9003 INSTANCE_ID
9009 SCENE_LINK
9014 NOTIFICATION_STATE
9015 NOTIFICATION_EVENT
9016 SMART_TASK_TEMPLATE
9017 NOTIFICATION_NVPAIR
9018 HS_ACCESSORY_LINK
9019 REACHABILITY_STATE
9020 LAST_SEEN
9023 NTP_SERVER
9024 TIME_REMAINING_IN_SECONDS
9029 VERSION
9030 REBOOT
9031 RESET
9032 FORCE_CHECK_OTA_UPDATE
9033 SESSION_ID
9034 UPDATE_FIRMWARE
9035 GATEWAY_NAME
9036 MASTER_TOKEN_TAG
9037 OTA_UPDATE
9038 GROUP_ID
9039 SCENE_ID
9040 SMART_TASK_TYPE
9041 REPEAT_DAYS
9042 START_ACTION
9043 END_ACTION
9044 TRIGGER_TIME_INTERVAL
9045 GROUP_SETTINGS
9046 START_TIME_HR
9047 START_TIME_MN
9048 END_TIME_HR
9049 END_TIME_MN
9050 SMART_TASK_ACTION
9051 SHORTCUT_ICON_REFERENCE_TYPE
9052 GATEWAY_REBOOT_NOTIFICATION_TYPE
9054 OTA_UPDATE_STATE
9055 GATEWAY_UPDATE_PROGRESS
9056 GATEWAY_UPDATE_DETAILS_URL
9057 SCENE_INDEX
9058 SCENE_ACTIVATE_FLAG
9059 CURRENT_TIMESTAMP
9061 COMMISSIONING_MODE
9063 AUTH_PATH
9064 SESSION_LENGTH
9066 OTA_TYPE
9068 IKEA_MOODS
9069 UPDATE_ACCEPTED_TIMESTAMP
9070 USE_CURRENT_LIGHT_SETTINGS
9071 GATEWAY_TIME_SOURCE
9090 CLIENT_IDENTITY_PROPOSED
9091 NEW_PSK_BY_GW
9994 TIME_ARRAY
9995 GROUP_LINK_ARRAY
15001 DEVICES
15002 HS_LINK
15004 GROUPS
15005 SCENE
15006 NOTIFICATIONS
15009 SWITCH
15010 SCHEDULES
15011 GATEWAY
15012 GATEWAY_DETAILS
15013 LIGHT_SETTING